FAQ
Phenomena
Cause of Malfunction
Power switch is o
No response from
control panel
A/C Power failure
operation
Lithium battery backup
power exhausted
Panel not in learning
status
Accessories cannot
Accessories not triggered
connect to control
for learning
panel
When learning, 3 beeps
are heard from panel
Remote control is not
learned to control panel
No response from
the control panel
by operating
Out of range between
remote control
remote control and panel
RFID card/tag fail
RFID card/tag not connected
to disarm
to the panel
Touch keyboard fail
Not logged onto the
to make related
setting menu.
setting
Speci cations
Product Name
PSTN/LCD/RFID Touch Alarm System
Model No.
S2
Power Supply
Input: AC 110V-240V, 50/60Hz
Output: DC 12V 500mA, 6Wh
Standby Current
≤ 90mA
Alarm Current
≤ 300mA
Backup Battery
2 Cells of 3.7V 800mAh Li-ion Battery(BL-5B)
Internal Siren Volume
95dB
Radio Frequency
315MHz or 433MHz (±75KHz)
25
All manuals and user guides at all-guides.com
Troubleshot Method
Open battery compartment,
turn on the power
Contact local main power
supply bureau
Connect to main power with
adapter
Make sure the panel set in
learning status
Make sure the triggered
accessories transmit signal
to panel for learning
This means accessory has
been coded already
Follow the manual and connect
the remote control to panel
No more than 80 meters in
open area
(no interference)
Signal repeater could be added
Follow the work manual and
code RFID card/tag to the panel
Input the correct admin code,
press
[ Enter ]
and log on menu
setting
Maximum Stored Phone No.
6 alarm Phone No. and 2 CMS No.
Maximum Remote Controls
10 pcs
Maximum Sensors
50 pcs
Maximum RFID Tags
50 pcs
Maximum Event Logs
150 events
Housing Material
ABS plastic
Operation Condition
Temperature: -10°C~ 55°C
Humidity: 80%RH (non-condensing)
Dimension (L x W x H)
185x130x27mm
Wireless Remote Control
Arm
Stay
Arm
Press
[
r A
m
]
when one beep is heard and the Arm LED Indicator lights on.
Note!
If Exit Delay is activated, all zones except the 24-hour zone will
enter Arm state after the set delay time.
The delay sensors will be armed after delay time.
Disarm
Press the
[Disarm
Disarm state when two beeps are heard and the Arm LED Indicator goes
out.
When alarm is activated, the siren will hoot. Press the
the system is disarmed after two beeps are heard, and the Disarm LED
Indicator lights on. But the LED indicator of triggered zone keeps ashing
for further checking.
Press
[Disarm
Home Mode
Press
[ Stay
Mode when one beep is heard and the Home Mode LED Indicator lights on.
All the Normal Sensors are armed except the Home Mode Sensors which
are disarmed so that users can move freely at home.
Mute Mode
When arm or disarm the system, the control panel will beep once or twice.
If siren beep is not needed, operationas follows :
Press
[
Stay
or
[Disarm
]
disturbing other people.
Emergency Call
In any condition, once the
the system goes into emergent alarming state with siren hooting,
meanwhile the panel will autodial pre-stored alarm phone numbers.
LED Indicator
Disarm
Panic
button on the remote control, the system enters Arm state
]
button on the remote control, the system enters
[Disarm
]
button again, the alarming zone indicator goes out.
]
button on the remote control, the system enters Home
]
button on the remote control, then press
button. The system is armed or disarmed in mute without
[
S
O
S
]
button on the remote control is pressed,
]
button,
[Arm
]
26

Publicité

loading