Instruction manual
WATER DRAINAGE
Manual(Figure 12)
Once the unit shuts down upon full water, turn off the unit and unplug
the power plug.
Put a tray for the water below the water outlet at the back of the unit.
Screw off the drain cap, unplug the water plug and water will flow out.
Tilt the unit slightly backward when draining.
If the water tray is full before the unit is empty block the water outlet
with the water plug as soon as possible to prevent the water from
flowing onto the ground or carpet.
Once the water is fully drained, insert the water plug and screw on the
water cap tightly.
Turn on the unit only after the water plug and drain cap are installed properly;
otherwise, the condensate of the unit will flow onto the ground or carpet.
Continuous drain (Figure 13 + 14)
1. Screw off the water cap insert a 13mm PVC drain hose 8mm-10mm into
the water outlet.
2. Connect the drain hose to the toilet or outdoor.
3. When operating in the heating mode, adopt continuous drain; other-
wise, the unit may shut down due to full water.
4. Put the drain hose in an inaccessible place at a height not above the
water outlet and keep the drain hose free from flexure.
Maintenance and Servicing
Prior to maintenance and servicing of the unit, turn off the power and
unplug the plug.
Clean the surface of the unit with wet soft cloth. Do not use chemical
solvents such as alcohol and gasoline; otherwise, the surface of the air-
conditioner may be damaged.
Clean the filters once every two weeks. If the filter frame and filter are
clogged with dust, the function of the air-conditioner may decrease
Take out the filter frame gently in the direction shown by the arrow (as
shown in Figure 15 + 16).
Put the filters into warm water (about 40°C) to which neutral cleaner is
added for cleaning and then dry them in the shade.
Make sure the filters are completely dry before placing them back in the
unit.
8
All manuals and user guides at all-guides.com
TROUBLESHOOTING
Problem/fault
indication
The air-conditioner
does not work
Bad cooling or heating
effects
Large noise
The compressor does
not work
The remote control
does not work
Display E1
Display E2
Display E4
Full water indicator
illuminates
Cause
Remedy
No power
Connect the unit to a live
Full water indicator
socket and turn it on.
illuminates?
Drain the water stored in the
Ambient temperature too
unit.
low ?
It is recommended that this
The room temperature is lower
unit be operated at 10-35°C.
than the set temperature in the
Change the set temperature
cooling mode.
There is direct sunlight
Draw the curtain on.
The doors and windows are
Close the door and window
open, the room is crowded or
and add new air-conditioners
there are other heat sources
Clean or replace the filter
in the cooling mode
mesh
Filter mesh very dirty
Remove the obstruction
Air inlet or air outlet clogged
Air-conditioner not put on a
Put the air-conditioner in a flat
flat surface
and firm place (may reduce
noise)
Initiation of overheat
Wait 3 minutes until the
protection.
temperature decreases and
then turn on the unit
Too long a distance
Bring the remote control
The remote control does not
close to the air-conditioner
point toward the receiving
and ensure that the remote
head of the remote control
control points toward the
The batteries have no
receiving head of the remote
electricity
control.
Replace the batteries
Pipe temperature sensor
Check the pipe temperature
failure
sensor and related circuits
Room temperature sensor
Check the room temperature
failure
sensor and related circuits
Anti-freeze protection
Restore the functions
automatically once defrozen.
The water in the baseplate
Drain the water in the
of the unit reaches the full
baseplate.
water level