OPERATION INSTRUCTIONS OF THE CONTROL PANEL
1. On/Off Button
2. Mode Button
3. Up/Down Button
4. Fan Button
5. Timer Button
6. Double 88 display area
7. Celsius/ Fahrenheit degree indicator
8. Timer indicator
OPERATION INSTRUCTIONS:
When the unit be plugged in for the first time, the buzzer will beep,
the display will show the ambient temperature and the temperature
display range is 10—35 °C. The unit enters the standby mode.
Press the on off button to start or shut down the unit. The unit
will enter in the cooling mode. The fan speed is high and the set
temperature is 23°C.
Press the mode button to switch among cooling, air supplying,
and drying modes. In the meanwhile, corresponding indicators will
illuminate.
Cooling mode: Press Mode Button to choose this mode. In this mode,
All manuals and user guides at all-guides.com
9. High/Low indicator
10.Full water indicator
11.Cool indicator
12.Dehumidify indicator
13.Fan indicator
14.Sleep mode indicator
15.Remote control sensor location
press the Up/Down Button to set desired temperature. The temperature
range is 17~ 30°C. One press makes the temperature rise or fall 1°C. Press
Fan Button to choose suitable fan speed. Press Timer Button + Down
Button together and to choose Sleep mode. Under this mode, after the
unit operates for 2 hours, the setting temperature raises 1°C automatically.
After operating for another 2 hours, the setting temperature raises 1°C
again. After that, the setting temperature won't change.
In the dry mode, if the ambient temperature is higher than 17°C, the
compressor will start. When the ambient temperature will come below
15°C, the compressor shuts down. When the ambient temperature rises
to be higher than 17°C, the compressor starts again.
In the air supply mode, only the fan motor works.
Fan button
The fan will operate in the following manners in the cooling mode (except
the sleep mode) and air supply mode: high > low > high.
Timer button
During operation press the Timer button to enter the shutdown time.
During standby press the Timer button to enter the start time. In the
meanwhile, the timer indicator will illuminate.
Press the Timer button to enter the timing function (start/ shutdown).
Use the up or down button to set the desired time in hours.
After the start or shutdown time is set, the timer indicator will
extinguish and the ambient temperature is displayed.
Up/ down button
Press the up button or down button when displaying the ambient
temperature, the ambient temperature will change to the desired
temperature (the unit will not respond to this operation in the air supply
and dry modes).
In the cooling mode, the temperature setting range is 17~30°C.
Press the up and down button simultaneously to switch between the
Fahrenheit degree and Celsius degree. When the Celsius degree is
displayed, the Celsius degree indicator illuminates.
Air conditioner
EN
7