CHECK:
1)
Main gas line to manifold connection.
2)
Rotisserie
(I.R. Burner) gas line connection.
3)
Bulkhead and gas supply hose connection.
4)
Bulkhead to regulator connection.
5)
Regulator to hose connection.
z_ WARNING:
if there is a leak at connection (1,2, 3, 4, or 5),
retighten
the fitting with a wrench and recheck for leaks with
soap and water solution.
If a leak persists after re-tightening
the fitting,
turn off the
gas. DO NOT OPERATE THE GRILL. Contact
the Customer
Service Representative
in your area using the contact
information on our web site. Log onto www.weber.com
®.
6)
Bulk head to side burner hose connection.
7)
Side burner hose to quick disconnect
connection,
side burner valve and orifice
connections.
8)
Hose to quick disconnect
connection.
9)
Valves to manifold connections.
Z_ WARNING:
If there is a leak at connections
(6, 7, 8, or 9),
turn off the gas. DO NOT OPERATE THE GRILL. Contact
the Customer
Service Representative
in your area using the
contact
information on our web site.
Log onto www.weber.com
®.
When leak checks are complete, turn gas supply off at the source and rinse connections
with water.
REINSTALL
CONTROL PANEL
Parts required:
control panel, screws and burner control knobs.
Hook the top edge of the control panel onto the control panel brackets on either side of
the front of the cooking box.
Line up screws with screw holes on both the control panel bracket and the frame.
Tighten screws.
Place corresponding
control knobs onto the valve stems.
@@
®
*The grill
illustrated
may have
slight
differences
than the model
purchased.