Venting Requirements
• Vent system must evacuate to the exterior –
Outside (through the roof or side wall).
• DO NOT terminate the vent system in an attic or
other enclosed area.
Use rigid metal/aluminum vent only.
• NEVER use plastic vent or plastic vent cover.
• Always keep the duct clean to ensure proper
airflow.
• Calculate
the
following
installation:
1. Distance from the floor to the ceiling.
2. Distance between the floor and the
countertop/cooking element.
3. Distance between the range hood and the
countertop/cooking element which is
recommended at 28" to 30''.
4.
Height of hood and duct cover with the
cabinet.
For the most efficient & quiet operation:
• It is recommended that the range hood be
vented vertically through the roof through 6"
(15.3 cm) round metal/aluminum vent or
vented horizontally through the wall through
a rectangular vent measuring 3 ¼'' x 10''.
• The size of the vent should be uniform.
• If venting vertically, do not use more than
three 90° elbows. Do not install two elbows
together.
• Make sure there is a minimum of 24" (61 cm)
of straight vent between the elbows if more
than one elbow is used.
The length of vent system and number of
elbows should be kept to a minimum to
provide efficient performance.
• The vent system must have a damper. If roof
or wall cap has a damper, DO NOT use damper
(which is supplied) on top of the range hood.
• Use duct tape to seal all joints in the vent
system.
• Use caulking to seal the exterior wall or roof
opening around the cap.
Height & Clearance
figures
before
Ceiling
heigh
23
Cabinet
height
Range
hood
height
Min: 28"
Max: 30"
t
Countertop/
Cooking element
36" standard
counter
height
Cabinet
Range hood