GROUP R -
disp.
277 v.FLt
Visualization Filter
Disabled
disab.
Pitchfork filter (Default)
ptcHf
First Order
f i.ord.
First Order with Pitchfork
f i.or.p .
2 Samples Mean
2 sa.m.
...n Samples Mean
....
10 Samples Mean
10.sa.m.
278 vi.d.2
Visualization Display 2
Selects visualization on display .
Command 1 setpoint (Default)
c.1.SPv
Percentage of command output 1
ou.Pe.1
279 tMo.d.
Timeout Display
Determines the display timeout
Disabled. Display always ON
diSab.
(Default)
15 seconds
1S S
1 minute
1 Min
280 tMo.S.
Timeout Selection
Selects which display is switched off when Display Timout expires
Display 1
disp .1
Display 2 (Default)
disp .2
Display 1 and 2
dsp .1.2
Display 1, 2 and led
d.1.2.Ld.
282 v.out
Voltage Output
Selects the voltage on the sensors power terminals and of the digital outputs (SSR).
12 volt (Default)
12 v
24 volt
24 v
283 ScL.t.
Scrolling Time
Select the duration for the visualization of the user menu data, before returning to the default
page.
3 seconds
3 s
5 seconds (Default)
s s
10 seconds
10 s
30 seconds
30 s
284 d.SP.F.
Display Special Functions
Special functions disabled
diSAb.
Shows the setpoint on display 1 and the process on display 2 (only if Par. 278
SWAP
on
c. 1 .SPv
285 nFc.L.
NFC Lock
NFC lock disabled: NFC accessible.
diSAb.
NFC lock enabled: NFC not accessible.
EnAb.
- Display and interface
)
5 minutes
5 Min
10 minutes
10Min
30 minutes
30Min
1 hour
1 h
1 minutes
1 MiN
5 minutes
5 MiN
10 minutes
10MiN
Manual scroll
MAn.Sc.
vi.d.2
User manual - ATR224 - DRR224 - 29