NEPTUNE 1, NEPTUNE 2
NEPTUNE 2 Special
4 Control / Operation
4.1
Switching on the
cleaner
NOTE!
Always remove any dirt from the
nipple before connecting the spray
lance to the spray gun.
4.2
Connections
4.2.1 Connecting the spray
lance to the spray gun
4.2.2 Hot water operation (up
to 100°C)
IMPORTANT!
In the case of appliances with a
hose reel:
In hot water mode, unwind the
high-pressure hose fully from the
hose reel, as otherwise the hose
reel may become warped due to
the effects of the heat.
4.2.3 Steam operation (over
100°C)
1)
Beware of hot water and
steam discharge up to
150°C when operating in
steam stage.
12
All manuals and user guides at all-guides.com
A
0
A
B
1. Move the main switch into
position 'Cold Water' (A)
The control electronics sys-
tem performs a self-test, all the
B
LEDs light up once.
The motor starts
lights up.
2. Ventilate the machine for air
by activating the spray gun
3. When the water flow is even,
continue with the following
steps
1. Pull the blue quick-release
grip (A) of the spray gun
backwards.
2. Insert the nipple of the spray
lance (B) into the quick-
release connection and re-
lease it.
3. Pull the spray lance (or other
C
accessory) forwards to check
that it is securely attached to
the spray gun.
1. Move main switch into the
position 'Hot Water' (B) and
select the required tempera-
ture on the temperature con-
trol
2. Unlock the spray gun and ac-
tuate it
The burner switches on.
In case of interruptions in work:
Also be sure to insert the safety
catch even during short interrup-
tions in work (see Fig. in section
6.1)
1. Replace the standard noz-
zle with the steam spray
nozzle (See catalogue for
accessories).
2. Open cover.
3. Turn the twist grip on the
safety control block com ple-
te ly to the left (anti clock wise
direction).
4. Turn the main switch into
position 'Hot Water'.
5. Select temperature (over
100°C).
1)
Options / model variants
Original instruction