Télécharger Imprimer la page

Webasto Thermo 230 Instructions De Montage page 58

Masquer les pouces Voir aussi pour Thermo 230:

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
Th23_EA_degbfr_g.book Seite 54 Dienstag, 15. Februar 2005 2:03 14
Exhaust pipe
Thermo 230/231/300/301/350
9
Exhaust pipe
The opening of the exhaust pipe must not point towards the front of the
vehicle.
The exhaust pipe opening must be located so that it cannot become
clogged with snow and mud.
Rigid pipes of unalloyed or alloyed steel with a minimum wall thickness
of 1.0 mm or flexible piping of alloyed steel only must be used as
exhaust line. The exhaust pipe is secured to the heater using a clamping
collar, for example. See the statutory regulations for other requirements.
Maximum dimensions of the exhaust pipe:
– Internal diameter: 70 mm
– Maximum line length:
5 m without the combustion air intake extension
– Total length of air intake line and exhaust pipe max. 5m
– Maximum bend: 270°
NOTE:
If the exhaust line is installed near heat-sensitive parts, it must be
insulated.