5.2 ID Number Setting
The Eyseo Pan / Tilt dome camera has an ID setup switch. The switch numbers
1 – 4 are used for ID setup (max. 15 cameras can be used, each with a separate ID),
switch 5 – 6 defines the Baud Rate (2400, 4800 or 9600), switch 7 selects the Protocol
(NATIVE or PELCO) and switch 8 sets the Alarm Type (NO=Normally Open or
NC=Normally Closed).
NATIVE ID Position Setup:
ID
SW-1
1
ON
2
OFF
3
ON
4
OFF
5
ON
6
OFF
7
ON
8
OFF
9
ON
10
OFF
11
ON
12
OFF
13
ON
14
OFF
15
ON
ID Position Switch
SW-2
SW-3
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
22
SW-4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON