9.3
FLAME CHARACTERISTICS
It's important to periodically perform a visual check of the pilot and
burner fl ames. Compare them to the illustrations provided. If any fl ames
appear abnormal call a service person.
9.4
RESTRICTING VERTICAL VENTS
Vertical installations may display a very active fl ame. If this appearance is not desirable, the vent exit must
be restricted using a restrictor vent kit. Refer to "ACCESORIES" in the "REPLACEMENTS" section for the
appropriate kit. This will reduce the velocity of the exhaust gases, slowing down the fl ame pattern and creating
a more traditional gentle fl ame appearance. Specifi c instructions are included with the kit.
All manuals and user guides at all-guides.com
3/8" - 1/2"
(9.5mm - 12.7mm)
FLAME MUST
ENVELOP UPPER
3/8" TO 1/2"
(12.7mm - 9.5mm) OF
THERMOCOUPLE &
THERMOPILE