7.0 WIRING DIAGRAM / ELECTRICAL INFORMATION
WARNING
EN
!
DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED
SERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE
ELECTRICAL CIRCUIT.
RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE
APPLIANCE WALL SWITCH. INCORRECT WIRING WILL DAMAGE CONTROLS.
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIAN
ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI/NFPA NO. 70 IN
THE UNITED STATES.
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT,
WITH THE GLASS DOOR OPENED OR REMOVED.
69.2
The NIGHT LIGHT is provided with a manual "in-line" switch to turn the light on and off. There are alternate
methods of operating the light.
An example of one method would be to "hard-wire" a wall switch. The switch could be installed in a desired
location to operate the NIGHT LIGHT plugged into one of the two receptacles on the appliance junction box.
The other receptacle would still have power to operate other accessories (see schematic below).
This switch could be:
• Toggle
• Photo cell
• Remote
• Motion Sensor
All switches are available at your building store.
BEFORE
AFTER
SWITCH
LIVE
LIVE
NEUTRAL
NEUTRAL
W415-1103 / A / 08.07.13