USE OF MOTORS
The ELNOR motor is intended for industrial use only. The motor should not be used until the
machine in which it is to be installed had met all the necessary approval and regulations. Before
installation, the user must check if the group and protection class, marked on the motor label,
corresponds with the requested conditions.
Zones
1)
Broad definitions of the
2)
zones ( for guidance
only)
IEC/EN 60079-10-1
1
An area in which it is
expected that an explosive
gas atmosphere will
occur occasionally during
normal operation.
Under no circumstances may Elnor motors be used in zone0
1) - Motors of- Zone 1 can also be used in Zone 2
2) - Motors which are certified for gas must not be used in dust or in hybrid mixtures! Hybrid mixtures: when explosive gas and dust atmospheres occur
simultaneously.
Temperature classification of the motor depends on the internal thermal protection and it is given
on the name plate.
Under no circumstances should a lower temperature class be used to replace a higher
temperature class motor (ie. T3 should not replace a T6).
INCOMING INSPECTION
When receiving the motors, check if any damage has occurred to the packaging of the motors
during transportation. If so, immediately notify the carrier, the insurance company and supplier.
Failure to do so may invalidate any possible claims.
Inspect the following after packaging has been removed:
- Check for any damage to the motor;
- Check nameplate data to ensure correct motor has been received;
- Check if dimensions and colour are in compliance with your specifications;
- Rotate the shaft by hand to make sure it is turning freely;
- Make sure the motor was not exposed to excessive dirt and moisture during transportation and
storage.
In the unlikely event of a claim, please contact our Sales Office.
Do not use the motor when damaged.
Ce document doit être transmis et utilisé inchangé et dans son intégralité. L'utilisateur est responsable de vérifier soigneusement
la validité de ce document concernant son produit.
page 66 de 80
ELNOR MOTORS NV
ZONES AND EQUIPMENT CATEGORIES
Equipment
category
2014/34/EU
2
Table 1 zones and equipment categories
TEMPERATURE CLASS
T
MAXIMUM SURFACE
CLASS
TEMPERATURE
T1
450°C
T2
300°C
T3
200°C
T4
135°C
T5
100°C
T6
85°C
Table 2 - Temperature class
Instruction Manual Induction Motors 2021-05-11revision 21
Equipment
Equipment
protection level
integrity
IEC/EN 60079-0
requirements
Gb
Equipment must be
safe under normal
operation, expected
malfunction.