ELECTRICAL REQUIREMENTS
WARNINGS
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove the ground prong.
Do not use an adapter
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock
Wiring Requirements
115 volt (103 min.---127 max)
(6K-8K) 0-8 amps
(10K-12K) 0-12 amps
(6K-8K) 10-amp time-delay fuse or
circuit breaker
(10K-12K) 15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only
Recommended Ground Method
For your personal safety, this air conditioner must be grounded. This air
conditioner is equipped with a 3 prong power supply cord with a
grounded plug. To minimize the possibility of electrical shock, the cord
must be plugged into a 3 prong outlet and grounded in accordance with
all local codes and ordinances. If a 3 prong outlet is not available, it is
the CUS-tomer's responsibility to have a properly grounded 3 prong
outlet installed by a qualified electrician.
It is the customer's responsibility:
● To contact a qualified electrician
● To assure that the electrical installation is adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70 - latest
edition, and all local codes and ordinances.
The electrical ratings for your air
conditioner are listed on the model
and serial number label located on
the front left side of the unit (when
facing the front).
Specific electrical requirements are
listed in the chart below. Follow the
requirements below for the type of
plug on the power supply cord.
Power Supply Cord
04