3. Installation Safety
• Refrigerant Leak Detector
• Appropriate Installation Location
Please note that:
1. The installation site should be in a well-ventilated condition.
2. The sites for installing and maintaining an air conditioner using Refrigerant
R32 should be free from open fire or welding, smoking, drying oven or any other
heat source higher than 548 ℃/ 1018 ℉ which easily produces open fire.
3. When installing an air conditioner, it is necessary to take appropriate
anti-static measures such as wear antistatic clothing and/or gloves.
4. It is necessary to choose the site convenient for installation or maintenance
wherein the air inlets and outlets of the indoor and outdoor units should be not
surrounded by obstacles or close to any heat source or combustible and/or
explosive environment.
5. If the indoor unit suffers refrigerant leak during the installation, all the
personnel should go out till the refrigerant leaks completely for 15 minutes. If
the product is damaged, it is a must to carry such damaged product back to the
maintenance station and it is prohibited to weld the refrigerant pipe or conduct
other operations on the user's site.
6. It is necessary to choose the place where the inlet and outlet air of the indoor
unit is even.
7. It is necessary to avoid the places where there are other electrical products,
power switch plugs and sockets, kitchen cabinet, bed, sofa and other valuables
right under the lines on two sides of the indoor unit, and also prevent
mechanical damage from occurring.
USING YOUR AIR CONDITIONER
Electronic Control Panel & Remote Control
NOTE: This display always shows the room temperature in Fan Mode
except when setting the Set temperature or the Timer.
AUTO
SPEED
9
8
1
AUTO
MODE
7
6
5
4
The left picture is the schematic
diagram of a refrigerant leak
detector.
2
3