5 EASY STEPS TO OPERATE YOUR ANGELCARE
STEP 1. SENSOR PAD
Place Sensor Pad under crib mattress, directly under where baby sleeps (Figures 1 and 2). Printed side of Sensor Pad MUST face up.
DO NOT place any bedding or linen between crib mattress and Sensor Pad.
Sensor pad must rest on a completely flat and rigid surface.
If your crib has a flexible or uneven base (metal spring base, etc.), place a piece of plywood measuring at least 400 mm X
600 mm X 6 mm (16" X 24" X 1/4") under the sensor pad to create a firm surface.
WARNING: Possible entanglement or strangulation injury. Keep all cords out of baby's reach.
Cribs with metal spring base: Route sensor pad cord through metal spring base in the center of crib (figure 1A).
Cribs with plywood type base: If your plywood base has air holes, route sensor pad cord through air hole. Otherwise, if your plywood
base does not have air holes, bring sensor pad cord to end of the crib (figure 1B).
SECURE SENSOR PAD CORD TO CRIB LEG USING A TIE WRAP. RUN SENSOR PAD CORD ON FLOOR TO
ENSURE CORD IS OUT OF BABY'S REACH. KEEP NURSERY UNIT AT LEAST 380 MM (15") AWAY FROM CRIB.
STEP 2. NURSERY UNIT (TRANSMITTER)
• Insert 4 AAA batteries into Nursery Unit (for battery backup in case of power failure).
• Connect Sensor Pad to Nursery Unit (Figures 3 and 6).
• On the back of the Nursery Unit, select 1 of the 3 functions of how you want to monitor your baby from the Parents Unit:
Sound & Movement: To hear sounds, see sound lights and hear a "Tic" sound with every movement baby makes.
Tic off: Same as Sound & Movement function BUT without the "Tic" sound.
Sound Only: To hear sounds and see sound lights on Parents Unit.
• Connect AC adapter to Nursery Unit and plug adapter into an electrical outlet.
NOTE: The sensitivity adjustment has been preset. DO NOT ADJUST UNLESS NECESSARY. If poor capture of movement (orange
flashing light) or false alarm occurs, consult the Movement Sensitivity Adjustment section.
STEP 3. PARENTS UNIT (RECEIVER)
Model AC201: Insert 4 AAA batteries into Parents Unit. Or, connect AC adapter to Parents Unit and plug adapter to an electrical outlet.
Model AC201-R: The pre-installed NiMh rechargeable batteries need to be charged for 15 hours continuously before first-time use.
To charge, connect the AC adapter to the Parents Unit. Plug AC adapter to an electrical outlet (Figure 4). The batteries will charge as
long as it is connected to a powered AC adapter. The position of the switches will not effect charging.
For longest battery life, recharge the Parents Unit when the orange Low Battery light flashes. Batteries need to be charged for
12 hours continuously.
NOTE: Use only rechargeable batteries in Parents Unit. Do not use Alkaline batteries in Parents Unit.
• Adjust the volume control to the desired level.
STEP 4. TO USE MONITOR
Place baby in crib and switch both units ON by selecting either channel A or B. If reception is not clear, switch to other channel. Make
sure both units are on the same channel. When removing baby from crib, switch Nursery Unit to the OFF position. If you forget to
switch OFF, a "pre-alarm Tic" will sound after 15 seconds as a reminder.
To avoid feedback (whistling sound), keep both units at least 3 meters apart (10 feet).
STEP 5. BATTERY MODE
• When unplugging AC adapter from each unit, make sure unit is switched OFF. Otherwise, unit will revert to battery mode.
• The monitor will revert to battery mode during a power failure only if batteries are inserted in both units.
Note:
• Test your Angelcare
®
Monitor BEFORE first-time use and then on a periodic basis.
• When monitor is in use, DO NOT use crib mobile or other crib accessories that produce vibrations. Alarm will not sound as monitor is
still detecting movement.
• The Angelcare
®
Monitor is perfectly safe. The Sensor Pad and cord is entirely passive. It carries no electrical current and does not
radiate any form of energy. The Nursery Unit emits only very low power radio signals through its antenna. These signals do not present
a safety hazard.
• Your monitor can be used in any crib or sleeping area (that has no motion or vibration) designed to safely hold a baby.
• To monitor twins, you need one AC201 Movement & Sound Monitor and one AC100 Movement Monitor. The sound monitor of the AC201
is sufficient to monitor both babies in the same room. Having two AC201 Movement & Sound Monitors in one room will cause interference.
Do not use the Angelcare
®
to monitor movement of two babies in one crib or bassinet.