TRIAC TEST
Failure of this component could jeopardise installation operation and safety.
That is why a control prior to every gate movement has been inserted.
Should there by any malfunction, the control unit locks and the open gate warning light blinks slowly.
PROGRAMMING THE GATE TRAVEL STROKE AND PAUSE TIME
The control unit autolearns the working and pause times during the programming procedure.
The programming procedure involves repeated operation of the P/P control (7, fig. 1), or otherwise the P/P control (terminal 8, fig. 2)
or the remote control (if memorised) can be used.
Important notes before programming:
A. Power up the control unit and check that the control inputs are operating correctly by checking the relative LEDs (the LEDs of the
NC contacts must be on).
B. Remove all obstacles from the gate's operating zone.
C. The limit switch LEDs (16, fig. 1) must be on when the gate is half-open. When the gate is moved to the closed travel limit position,
one of the LEDs (FCC) must go out; the other LED (FCA) must go out when it reaches the open travel limit position.
Programming:
1) Position the gate or door at mid-travel.
2) Press the PROG button (6, fig. 1) and hold it down for about 5 seconds, until LED LD1 (17, fig. 1) remains constantly on.
The control unit is now in programming mode.
3) Press the P/P button (part 7 of fig.1). The motor then starts a closing manoeuvre. If the motor is running backwards, cut off the
power, invert the motor phases and repeat the procedure.
4,5) Once the motor has reached the stroke limit, it stops and then the opening stroke starts automatically.
6) Once the opening stroke is complete, the motor stops. The control unit starts the pause time registration phase.
7) Once the desired pause time has lapsed, press the P/P button. The motor then starts the closing manoeuvre.
8) Once the closing stroke is complete, the motor stops. End of programming, led L1 switches off.
NOTE: if the encoder is detected during the motor movement, LED L1 flashes.
PROGRAMMING PEDESTRIAN OPENING
Pedestrian opening is already programmed in the factory at about 1-1.5 metres.
If this opening requires modification, proceed as follows using the PED input, terminal 10:
First, the total gate travel stroke must be programmed.
1) With the gate closed, access the programming mode by holding the PROG button down until LD1 illuminates
2) Press the PED button; the gate opens.
3) Press the PED button again, in the point required as the pedestrian opening position.
4) The gate stops and then closes. The control unit then quits the programming mode.
PROG.
STOP
P/P
5 sec.
Pause
time
PROG.
STOP
P/P
PROG.
STOP
P/P
End
GB
36