Cardin EVO2000 Instructions Pour L'utilisation Et La Programmation page 35

Motoreducteurs a 230 v pour vantaux coulissants industriels

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
Com. (Brown)
24V (Yellow)
Sec. 12Vac (White)
Sec. 24Vac (Orange)
ENCODER
motor
Tips for correct Installation:
1) The cross section of the cables should be calculated according to their length and absorbed current.
2) Do not use a single cable of the "multi-core" type for all the connections (line, controls, etc.) or in common with other equipment.
3) Use at least two cables for the installation, e.g.:
cable (A) minimum wire section 1.5 sq.mm
- power supply line - courtesy / flashing light line
cable (B) minimum wire section 0.75 sq.mm
- auxiliaries power supply - controls - safety contacts.
4) When the control cables are very long (over 50 metres), de-coupling is advisable with relays mounted near the control unit.
5) Any N.C. Inputs (photocells, limit switches, fixed safety edge and stops) that are not used In the control unit should be short-
circuited with the common terminal terminal.
6) All the N.C. contacts linked with the same input should be connected in series.
7) All the N.O. contacts linked with the same input should be connected in parallel.
TRANSMITTER
P/P
FC(1) Green
FC(2) White
PROG.
STOP
18
19
20
21
22
23
24
230V primary
transformer
P1
P2
(PED)
(P/P)
RECEIVER mod.
OC2
FCA
FCC
F0,3A
24V
28
30
27
29
31
Com. Motor (Black)
17
16
15
14
13
12
11
FT1
10
Jolly
Stop
9
8
P/P
7
Ch
6
Ap
5
4
3
2
1
F6,3A
230V
Condensatore
GB
RECEIVER
ANTENNA
power supply
photocells
with
FOTO-TEST
Tx
Rx
SPIA 24Vac CA
24Vac
Common input
FT1
Photocell input
JOLLY input
Stop input
Step/step input
CLOSING input
OPENING input
230V Courtesy light
230V Flasher
N
Power
Supply
230V 50Hz
L
34