ELECTRIC CONNECTIONS
Make sure that the mains power supply has been disconnected and make the electrical connections.
Take care when stripping cables not to reduce the insulation between terminals or other metal parts.
After making the connections, check the tightness of screw terminals once more.
THE INSERTION OF AN external, Independent DISCONNECTING SWITCH (not supplied) of suitable capacity for the load Is
envisaged for the control unit power supply.
Term. n.
1 (L)
2 (N)
3
4
5
4
6
12 (com)
7
12 (com)
8
12 (com)
9
12 (com)
10
12 (com)
11
12 (com)
13
24Vac
14
15
14
(Tx FT)
16 Braid
17 Control
18
19 (com)
20
19 (com)
33
Function / Device
Power supply
Flasher output
Courtesy light
OPENING command input
CLOSING command input
Step/step command input
Stop command input
Input with selectable function
Photocell contact input
Auxiliary device power supply
output
Gate open indicator light
Radio antenna input
Limit switch open
Limit switch closed
V/I max
/
230/6A
/
Connect to 230 V line.
230/0,5A
/
Switches on with motor in motion.
On form start of manoeuvre until 3 minutes after
230/0,5A
/
complete shutdown.
NO
/
Starts gate opening.
NO
/
Starts gate closing.
NO
/
See settings of dip-switches 1 and 2.
Blocks all functions.
NC
/
Connect this input to the common if it is not used.
NO/NC
See settings of dip-switches 3 and 4.
Reverses direction during closure.
NC
Connect this input to the common if it is not used.
/
24ac/
Power supply for receiver photocell, if the Fototest
/
300mA
function is used.
Signals gate status with different flashes.
24ac/
/
Power supply for transmitter photocell, if the Fototest
100mA
function is used.
Connection only necessary with receiver OC2 active.
/
Use aerials for frequency 433 MHz (50 Ohm)
NC
/
NC
Notes