The SINGLE SEQUENTIAL ACTUATION MECHANISM
is for use where precision fastener placement is desired.
The SINGLE SEQUENTIAL ACTUATION MECHANISM
may reduce the possibility of bodily injury to you or others
in the work area compared to the CONTACT ACTUATION
MECHANISM. This is because it is less likely to drive
an unwanted nail if you keep the trigger pulled and
accidentally bump the push lever against yourself or
others.
The SINGLE SEQUENTIAL ACTUATION MECHANISM
may also reduce the speed of operation compared
to the CONTACT ACTUATION MECHANISM. The
SINGLE SEQUENTIAL ACTUATION MECHANISM is
recommended to inexperienced users.
NOTE
● If all warnings and instructions are followed, safe
operation is possible with all two systems: SINGLE
SEQUENTIAL ACTUATION MECHANISM and
CONTACT ACTUATION MECHANISM.
● Always handle nails and package carefully. If nails
are dropped, collating plastic may be broken.
● After nailing:
1) disconnect air hose from the Nailer;
2) remove all nails from the Nailer;
3) supply 5 – 10 drops of metabo HPT pneumatic
tool lubricant into the air plug on the Nailer; and
4) open the petcock on the air compressor
tank to drain any moisture.
ADJUSTING THE NAILING DEPTH
● Disconnect the air hose from the nailer
before turning the adjuster.
To assure that each nail penetrates to the same depth, be
sure that:
1) the air pressure to the Nailer remains constant
(regulator is installed and working properly), and
2) the Nailer is always held fi rmly against the workpiece.
If nails are driven too deep or shallow into the workpiece,
adjust the nailing in the following order.
WARNING
1 DISCONNECT AIR HOSE FROM NAILER.
2 If nails are driven too deep, turn the adjuster to the
shallow side.
2
Too Deep
If nails are driven too shallow, turn the adjuster to the deep
side.
2
Too Shallow
3 Stop turning the adjuster when a suitable position is
reached for a nailing test.
4 Connect the air hose.
ALWAYS WEAR EYE PROTECTOR.
Perform a nailing test.
5 DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.
CHANGING THE EXHAUST DIRECTION
The direction of the exhaust vent can be changed by
turning the top cover.
1 DISCONNECT AIR HOSE FROM NAILER.
Exhaust
Vent
English
Adjuster
15
Disconnect air hose
Turn Adjuster
Flush
Turn Adjuster
Flush
Top Cover
1
Disconnect
air hose
19