FHSM 604 4I / FHSM 603 3I / FHSM 603 3I DZ / FHSM 603 3I SZ / FHSM 804 4I /
FHSM 803 3I / FHSM 302 2I / FHSM 604 4I WH / FHSM 603 3I DZ WH
Electrical connection
Connection terminals are revealed when the connection box cover is removed.
FRANKE hobs are supplied with a power cable.
Make sure the characteristics of the household electrical system (voltage,
X
Z
maximum power and current) are compatible with those of the appliance.
If the appliance is to be permanently connected to the power supply:
Install a device that enables disconnection from the power supply, with a contact
X
Z
opening distance (3 mm) that ensures complete disconnection in category III
overvoltage conditions.
Ensure the following:
X
Z
– Check that plug and socket are correctly dimensioned, according to the
appliance rating plate. Avoid the use of adapters and shunts as these could
cause overheating and burns.
– The plug and the socket can be easily reached and are positioned so that no live
part is accessible when inserting or removing the plug.
– The appliance does not rest against the plug when installed in the worktop.
– When replacing the power cable, please use the type cable indicated in figure 1
on pages 5 and 6.
– The earthing wire must be connected to the terminal marked with the earthing
symbol.
– The connection cable must lead through the relief safety device, protecting it
from accidental pulling out.
After electrical connection
Switch on all the hotplates for about 3 minutes to check the proper function.
X
Z
Power limitation settings
Power limitation setting is possible for all the following models:
FHSM 604 4I, FHSM 603 3I, FHSM 603 3I SZ, FHSM 603 3I DZ, FHSM 804 4I,
FHSM 803 3I, FHSM 604 4I WH, FHSM 603 3I DZ WH.
– Setting is possible only during the first two minutes after plug in the
appliance.
– The touch has to be unlocked and all heaters have to be switched off.
– The factory power setting is the maximum level.
– If there is a black out, power level set remains unchanged.
– 9 –
EN