5. PARTS LIST
Compressor type
.............................................................. DUO, DUO 2, DUO 2V ....
Installation, Operation and Maintenance Manual ..........................NP-DUO
Suction unit hose ( DUO, DUO 2V / DUO 2 (*), ø 30x4 m.....
Fitting ø 30 – ø 40 (*) .........................................................
Fuse (for DUO, DUO 2V / for DUO 2 (*), T6.3A/35 ...........
Wall stopper ........................................................................
Kay of the case
EK333
Applicable only for : Compressor with air dryer
Dryer output filter - 4KB-650
Set for discharge of condensate
Applicable only for: Suction aggregate LUZZANI AIRMATIC
Hose socket
(DUO, DUO 2V / DUO 2* )....................
Extra equipment :
Plug for mains connection,
Noise suppressor with filter
Noise suppressor with filter
Noise suppressor without filter DUO ..................................
Noise suppressor without filter DUO 2 ...............................
Wall-mounted noise suppressor with filter ...........................
Wall-mounted noise suppressor without filter ......................
Autodrain
AOK 2 ...........................................
6. TECHNICAL DATA
Compressor
Suction pump
Nominal voltage / frequency (*)
Capacity at 5 bars
Capacity at 5 bars with dryer
Capacity at 5 bars with KJF-1
Efficiency of suction pump under-pressure at
5 kPa
Suction pump underpressure
Maximal current
Capacity of air tank
Working pressure of compressor unit
Safety valve
Noise level
Duty cycle without dryer
Duty cycle with dryer
Dimensions of compressor w x l x h
Dimensions of compressor packaged in cardboard
w x l x h
Weight of compressor
Weight of compressor packaged in cardboard
Compressor temp drying at atmospheric
condensation point
Version according to EN 60 601-1
Climatic conditions during storage and transport
Temperature : –25°C to +55°C, 24 h to +70°C
Relative air humidity : 10% to 90 % (no condensation)
NP-DUO-2
All manuals and user guides at all-guides.com
.......................................
....................................... 604011790
No.0299-0-0032
DUO .................................
DUO 2 ...............................
DUO (T*)
DK 50 PLUS
1
230 / 50
230 / 60
V / Hz
-1
Lit.min
75
-1
Lit.min
75
-1
Lit.min
75
800
-1
Lit.min
kPa
12
6.7 (7**)
A
8 (8.3**)
Lit.
25
bar
4.5 – 6.0
bar
8.0
47
dB(A)
Continual S1-100%
Intermittent
S 3 – 60%
560x637x1250
mm
600x680x1300
mm
110/119 **
kg
116/125 **
kg
- 20°C
Climatic operation conditions
Temperature : +5°C to +40°C
Relative air humidity : 70%
- 22 -
.................
072000017
.................
062000538
..................
038100004
................
023000276
.................
029000106
024000653
..................
..................
062000011
...................
...
033200005
...................
603011849
...................
603011850
...................
...................
...................
...................
...................
603001163
...................
DUO 2 (T*)
DK 50 2V
2
230 / 50
230 / 60
140
140
140
2x800
12
13.9 (14.2**)
15.7 (16**)
25
5.0 – 7.0
8.0
51
Continual S1-100%
Intermittent
S 3 – 60%
560x637x1250
600x680x1300
125/135 **
131/141 **
- 20°C
Appliance of type B, class I
(*) - by special request
(**) - with dryer
DUO
1 pc
1 pc
2 / 4* pcs
2 / 4* pcs
2 / 4* pcs
2 pcs
1 pc
1 pc
1 pc
2 / 4* pcs
1 pc
1 pc
1 pc
1 pc
1 pc
1 pc
1 pc
1 pc
DUO 2V (T*)
DK 50 2V
1
230 / 50
230 / 60
140
140
140
800
12
10.8 (11.1**)
12.2 (12.5**)
25
5.0 – 7.0
8.0
51
Continual S1-100%
Intermittent
S 3 – 60%
560x637x1250
600x680x1300
113/123 **
119/129 **
- 20°C
06/2009