L 3709-115, L 3709-125, LE 9-10 125, L 10-10 125
Rotate safety guard to the required
position.
Quick-release guard
(LE 9-10 125, L 10-10 125)
t^okfkd>
tÜÉå=ìëáåÖ=íÜÉ=~åÖäÉ=ÖêáåÇÉê=Ñçê=êçìÖÜáåÖ=
çê ÅìííáåÖI=åÉîÉê=ïçêâ=ïáíÜçìí=íÜÉ=Öì~êÇK
Pull out the mains plug.
Loosen the clamping lever (a).
Adjust the guard.
Tighten screw (b) until the clamping lever
can just be clamped by hand.
Retighten the clamping lever.
A special quick-release cutting guard must
be used for cutting.
Attaching or changing the grinding
tool
Pull out the mains plug.
Press and hold down the spindle lock (1.).
Using the stop key, loosen the clamping
nut on the spindle in an anti-clockwise
direction and remove (2.).
Insert the grinding wheel in the correct
position.
Screw the clamping nut (1b), with flange
face up, onto the spindle.
Press and hold down the spindle lock (4).
Tighten the clamping nut (1b) with the
stop key.
Insert the mains plug into the socket.
Switch on the angle grinder (without
locking into position) and leave the angle
grinder running for approx. 30 seconds.
Check for imbalances and vibrations.
Switch off the angle grinder.
21