Technical Data
UTILIFINDER + :
Proximity alarm
Utility less than 30cm deep, indi-
cated by additional tone.
Depth Reading
0.3 to 3m. Typical depth accuracy
10% of depth
Environmental
IP54 shower proof
Protection
Batteries
6 x AA alkaline (IEC LR6 supplied)
Battery life
40 hours intermittent use (at 20°C)
Weight
2.7kg including batteries
UTILIGEN:
Power Supply
Household 13 Amp Plug Mains
230 Vrms
Width
61 mm
Height
47 mm
Length
103 mm
Environmental Con-
Indoor Use Only.
ditions
Temperature Range: 0 - 40 C
Rating Input Volt-
230V
age
Power Consump-
2VA
tion
Weight
255g
Leica UTILIFINDER + User Manual
All manuals and user guides at all-guides.com
UTILIDRAIN:
Frequency
Operating Depth
Range
Internal Battery
Typical Operating
Time
Instrument Dimen-
sions
Instrument diameter
Weight
Temperature Operat-
ing
Temperature Storage
Environmental Protec-
tion
8,192 kHz
3m (10ft)
1 x AA alkaline (IEC LR6 supplied)
40 hrs intermittent use at 20°C /
68°F
120mm / 4.7 Inches
38mm / 1.5 Inches
0.18 kg / 0.4 lbs
-20°C to +50°C / -4°F to +122°F
-40°C to +70°C / -40°F to +158°F
IP68 (IEC60259) Fully submersible
Submersion level: 3 bar pressure /
30m water