WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
4. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (C) in terminal box using
UL Listed wire connectors�
The range hood is designed to remove smoke, cooking vapors,
and odors from the cooktop area� For best results, start the hood
before cooking and allow it to operate several minutes after
the cooking is complete to clear all smoke and odors from the
kitchen�
The hood controls are located on the underside of the
range hood�
A
B
A. Light control
B. Blower control
C. Fan speed control
Range Hood Controls
Operating the light
1. Move the light switch to the "1" position to turn range hood
light to night light setting�
2. Move the light switch to the "2" position to turn range hood
light to full light setting�
3. Move the light switch to the "Off" position to turn range hood
light off�
5. Install terminal box cover�
6. Check that all light bulbs are secure in their sockets�
7. Reconnect power�
If you are installing an optional full width duct cover, follow the
instructions included with that product�
1. Install metal grease filters� See the "Range Hood
2. Check the operation of the range hood blower and light� See
RANGE HOOD USE
Operating the fan
1. Move the fan switch to the on position to turn the fan on� The
2. Move the fan switch to the Off position to turn the fan off�
Auto on fan
The range hood is equipped with a sensor to automatically turn
on the fan when excessive heat is detected in the control area�
When the fan switch is in the off position, this sensor will turn the
fan to high speed when necessary� When the heat decreases,
the fan will turn off�
C
When the fan switch is in the on position, the heat sensor is not
active, and the range hood functions normally�
Adjusting the fan
The fan has three speed controls� Move the fan speed switch to
"1" position for low speed, "2" position for medium speed, or "3"
position for high speed�
Thermal protector
The range hood is equipped with a thermal protector to avoid
overheating conditions� If the range hood shuts off while in use,
move fan slider switch to off to turn off the range hood� Wait
approximately 60 minutes, then move slider to on to restart the
range hood�
Install Vent Covers (Optional)
Complete Installation
Care" section�
the "Range Hood Use" section�
NOTE: To get the most efficient use from your new range
hood, read the "Range Hood Use" section�
fan will begin operating at the speed set on the fan speed
switch�
11