INOXPAN S.L.
ELECTRICAL CONNECTION
The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician who is aware of the normative regulations and respects
them scrupulously.
The electrical parts should always be protected after the building-in.
The necessary data of connection are on the stickers placed on the bottom of the
appliance.
The appliance should be separated from the mains by using a multipolar circuit breaker.
o The contact opening must be at least 3 mm.
The electrical circuit must be separated from the mains by adapted devices, such as circuit
breakers, fuses or (differential) contactors.
If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob or
oven.
Caution!
This appliance can only be connected to a network 230 V~ 50/60 Hz.
You should always connect the earth wire.
Respect the connection diagram.
Use the connecting cable that is attached to the device.
The green / yellow wire corresponds to the earth wire, the blue wire corresponds to the neutral
wire and the brown wire correspond to the phase.
Mains
230V~ 50/60Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Connecting the hob :
Monophase 230V~1P+N
Attach the earth cable to the terminal provided. The neutral conductor to terminal N, and the phase
L to terminal L.
Frequent loosening and screwing of the screws on the connection box risks damaging the
efficiency of the tightness once screwed. It is therefore advisable to keep screwing and
unscrewing to a minimum.
Ensure that the cables are correctly inserted and tightly screwed down.
4 weeks after installation, be sure to tighten again the screws in the terminal block.
Caution! Be careful to correctly engage and tighten the cables.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phase + N
3 x 2,5 mm²
equipped with a faulty earth connection.
Cable
H 05 VV - F
H 05 RR - F
20
EN
Protection calibre
16 A *