Before each fault elimination:
 switch off device
 wait for standstill of the beater
 pull out power plug
After each fault clearance, put into operation and recheck all security installations.
Problem
Motor does not start.
Unusual vibrations
Device starts but blocks under
slight load and cuts off auto-
matically.
In case of further faults or inquiries please contact your local dealer.
Type / Model
Year of construction
Motor power P
1
Motor
Speed (counter-rotating) n
with speed control
Beater diameter (Mortar beater / Disc beater)
Beater chuck
Beater length
Hand-arm-vibration on the handle
Measuring uncerntainty K
Volume of the material to be mixed
Weight
Measured sound power level L
Measured sound pressure level L
Measuring uncerntainty K
Safety class
Protection class
16
Possible cause
 No power supply (power failure)
 Mains cable defective.
 Motor or switch defect
 Beater defective.
 Chuck defective.
 Non-intended material to be mixed.
 Extension cable too long, or cross-
section too small.
 Socket too far away from main connec-
tion, and cross-section of connection
lead too small.
0
WA
PA
P
o
s
s
i
b
l
e
f
a
u
l
t
s
P
o
s
s
i
b
l
e
f
a
u
l
t
s
Remedy
 Check fuses (16 A)
 Exchange defect cable, respectively check ex-
tension cable, (by electrician)
 To correct the problem, refer to the manufacturer
or other approved service centre.
 Replace the beater.
 To correct the problem, refer to the manufacturer
or other approved service centre.
 Incorrect processing. Follow the processing in-
structions from the supplier.
 Extension cable at least 1,5 mm2 , maximum 25
m long.
 Cross- section of at least 2,5 mm2 in longer
cables.
T
e
c
h
n
i
c
a
l
d
a
t
a
T
e
c
h
n
i
c
a
l
d
a
t
a
AC-motor 230 V ~ 50 Hz
Mortar beater: 290 - 480 min
Disc beater: 380 - 620 min
140 mm / 114 mm
approx. 570 mm
a
h
approx. 90 litres
approx. 5.5 kg
II /
Never use defect lead
RL 1600 G
See last page
1600 W
(clockwise)
-1
(anticlockwise)
-1
M18
= < 2.291 m/s²
1.5 m/s²
98.7 dB (A)
87.7 dB (A)
3 dB (A)
double insulated
IP20
Technical modifications reserved!