4.4 Nordik 41 DV
All contents in this kit are required and must be installed.
The Kozy Zone Kit requires that the convection plates,
and insulation blanket to be removed to allow the hot
airflow to convect upwards into the air ducts installed on
the fireplace.
See additional requirements and installation information
in the appliance manual.
1. Remove the (13) sheet metal screws that secure the
top outer shell assembly. Pull this assembly straight
up around the exhaust stack to remove it from the
appliance. See the first image in Figure 4.15.
2. Remove the (4) cover plates where each cover plate
is secured with (4) sheet metal screws. See the sec-
ond image in Figure 4.15. Discard these cover plates.
Figure 4.15 - Nordik 41 Convection Plates and Insulation Removal
KZK-1510A
Figure 4.16 - Nordik 41 Screws Near Exhaust Stack
3. Remove (3) sheet metal screws from the top of the assembly
(see close up in Figure 4.16) and (2) sheet metal screws on the
side of the assembly (one screw on each side shown in the sec-
ond image of Figure 4.15). You are now able to seperate the two
sections of the top outer shell assembly. Remove and discard
both the insulation and the bottom section of the top assembly.
Additionally discard the (4) cover plates shown in the second
image of Figure 4.15.
4. Reinstall the top outer shell assembly on the appliance with the
previously removed (13) sheet metal screws.
5. Align the take off collars to the corresponding holes on top of the
appliance. Secure with screws previously removed. Install the
take off collars to the corresponding opening(s) on the plenum
(s). Use supplied screws.