4.0 Fireplace Preparation & Installation
4.1 Bellingham 38 and Bellingham 44
All contents in this kit are required and must be installed.
The Kozy Zone Kit requires that the convection baffle, lo-
cated above the firebox inside the appliance metal cabinet,
to be removed to allow the hot airflow to convect upwards
into the air ducts installed on the fireplace. You will also
remove the cover plates.
See additional requirements and installation information in
the appliance manual.
1. Remove the convection baffle from the appliance. Re-
cycle this panel as it is no longer needed. The baffle is
secured by a baffle clip with (2) screws in the front
center, and (2) screws right behind the upper edge of
the fireplace opening.
2. Remove (2) cover plates on top of the appliance (4
screws each).
3. Install the metal stand-off assembly and discard the
header heat shield.
4. Align the take off collars to the corresponding holes on
top of the appliance. Secure with screws previously
removed. Install the take off collars to the correspond-
ing opening(s) on the plenum(s). Use supplied screws.
Figure 4.1 - Bellingham 38 & 44 Convection
Baffle and Cover Plates
KZK-1510A
Figure 4.2 - Bellingham 38 & 44 Stand Off Assembly
Figure 4.3 - Bellingham 38 & 44 Air Flow with
Convection Baffle Removed
37
Rev. 10 — May 2023