•   the pump takes in air = check the
liquid level, operation of the foot valve
and the suction pipeline
•   the foot valve is blocked in the closed
position = replace or clean the valve
•   for self-priming pumps only: the
liquid column above the check valve
on the delivery pipeline prevents
self-priming of the pump = drain the
delivery pipeline check that check
valve does not retain liquid in the
delivery pipeline Repeat the start-up
procedure.
Pump performance is reduced
•   Pipelines obstructed = check pipelines
•   Pump is not primed correctly = repeat
the "pump priming" procedure
•   the pressure switch setting is low =
adjust the pressure switch
•   for self-priming pumps only: the in-
ternal valve has not closed = gradually
close a valve until there is a visible in-
crease in pressure or flow. then open
the valve gradually until the required
flow rate is reached.
Pump performance is unstable
•   Pump suction pressure too low or
cavitation = check the pump inlet
conditions
•   Suction pipe is partially obstructed
with impurities = clean the suction
pipe
•   leak from suction pipe = repair or
replace suction pipe
•   air in suction pipe = bleed the suc-
tion pipe, repeat the "pump priming"
instructions
•   for self-priming pumps only: the dif-
ferential pressure inside the pump is
too low = gradually close a valve until
delivery pressure stabilizes and the
noise level is reduced
the pump rotates in the opposite direc-
tion when shut down
•   foot valve or check valve defective or
blocked in the open position = remove
and clean or replace the valves
•   leak from suction pipe = remove and
repair suction pipe
the pump starts and stops frequently
•   the membrane inside the tank is
damaged = replace the internal mem-
brane of the tank
•   the gas pressure in the expansion
tank is incorrect with respect to the
pressure switch setting = adjust the
gas pressure to approximately the
pump intervention pressure minus
10%.
•   leak from foot valve = clean or repla-
ce the foot valve.
the pump does not stop
•   the pressure switch setting is incor-
rect (too high) = adjust the pressure
switch to within the pump pressure
limits
•   air in suction pipe = bleed the suc-
tion pipe, repeat the "pump priming"
instructions
DISASSemBly AND
DISPoSAl
Before any intervention on the
system, disconnect the electrical
mains. ensure that the electrical
power supply cannot be restored inadver-
tently.
•   Disconnect the pump electrically from
the system according to safety stan-
dards
ENGLISH