(TIG DC) Easy joining
Allows striking of the arc in pulsed current and timing of
the function before the automatic reinstatement of the
pre-set welding conditions.
Allows greater speed and accuracy during tack welding
operations on the parts.
Parameter setting: seconds (s).
Minimum 0.1s, Maximum 25.0s, Default off
312
Arc detachment voltage
Allows you to set the voltage value at which the electric
arc switch-off is forced.
It permits improved management of the various operat-
ing conditions that occur. In the spot welding phase,
for example, a low arc detachment voltage reduces
re-striking of the arc when moving the electrode away
from the piece, reducing spatter, burning and oxidisa-
tion of the piece.
Never set an arc detachment voltage higher than
the no-load voltage of the power source.
Minimum 0.0V, Maximum 99.9V, Default 45V
500
Allows access to the higher set-up levels:
USER: user
SERV: service
vaBW: vaBW
601
(U/D) Adjustment step
Permits adjustment of the variation step on the up-
down keys.
Minimum Off, Maximum MAX, Default 1
602
CH1 External parameter
Allows the management of external parameter 1 (mini-
mum value).
603
CH1 External parameter
Allows the management of external parameter 1 (maxi-
mum value).
606
U/D torch
Allows the management of the external parameter (U/D).
0=Off, 1=A
750
Measurements
Permits selection of the type of measurement to be
shown on the display 4.
A Real current
U Real voltage
751
Current reading
Allow the real value of the welding current to be dis-
played.
Allows the welding current display method to be set
(consult the "Interface personalisation" section).
752
Voltage reading
Allows the real value of the welding voltage to be dis-
played.
Allows the welding voltage display method to be set
(consult the "Interface personalisation" section).
3.2.2 Alarm codes
E01, E02
Temperature alarm
E04, E13
Communication alarm
E10
Power module alarm
E19
System configuration alarm
E20
Memory fault alarm
E21
Data loss alarm
E23
Memory fault alarm (RC)
E24
Data loss alarm (RC)
E40
System power supply alarm
E43
Coolant shortage alarm
28
3.2.3 Lock/unlock
Allows all the settings to be locked from the control panel with
a security password.
Enter set-up by pressing the encoder key for at least 5 seconds.
Select the required parameter (551) by rotating the encoder
until it is displayed within the central quadrant.
Activate the regulation of the selected parameter by pressing the
encoder button.
Set a numerical code (password) by rotating the encoder.
Confirm the change made by pressing the encoder button.
3.3 Rear panel
1
Power supply cable
Connects the system to the mains.
2
Gas fitting
3
Signal cable (CAN-BUS) input (RC)
4
Off/On switch
Turns on the electric power to the welder.
It has two positions, "O" off, and "I" on.
3.4 Sockets panel
1
Negative power socket
For connection of earth cable in electrode welding or of
torch in TIG.
2
Positive power socket
For connection of electrode torch in MMA or earth
cable in TIG.