8 TECHNICAL SPECIFICATIONS
Power supply voltage U1 (50/60Hz)
*
Zmax (@PCC)
Slow blow line fuse
Communication bus
Maximum input power (kVA)
Maximum input power (kW)
Power factor PF
Efficiency (µ)
Cos
Max. input current I1max
Effective current I1eff
MMA duty factor (40°C)
(x=50%)
(x=60%)
(x=100%)
MMA duty factor (25°C)
(x=80%)
(x=100%)
TIG duty factor (40°C)
(x=50%)
(x=60%)
(x=100%)
TIG duty factor (25°C)
(x=70%)
(x=80%)
(x=100%)
Adjustment range I2
MMA open circuit voltage Uo
TIG open circuit voltage Uo
Peak voltage Up
IP Protection rating
Insulation class
Dimensions (lxdxh)
Weight
Manufacturing Standards
Power supply cable
Length of power supply cable
*
This equipment complies with EN/IEC 61000-3-11.
*
This equipment does not comply with EN/IEC 61000-3-12. If it is connected to a public low voltage system, it is the responsibility of the
installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment may be
connected. (Consult the "Electromagnetic fields & interferences" - " EMC equipment classification in accordance with EN/IEC 60974-10" section).
34
TERRA 320 TLH
3x400V ±15%
-
25 A
DIGITAL
15.9 kVA
10.9 kW
0.68
88%
0.99
23.2 A
16.5 A
300 A
290 A
250 A
300 A
290 A
/
320 A
280 A
320 A
/
290 A
3÷320 A
61 Vdc
61 Vdc
11.5 kV
IP23S
H
620x240x460 mm
20.5 kg.
EN 60974-1/EN 60974-3/EN 60974-10
4x2.5 mm2
5 m