been stopped for 23 hours be given maximum priority in the starting order. This means that as soon as it is necessary to supply flow, it will be
the first to start. The devices configured as reserve have precedence over the others. The algorithm ends its action when the device has
supplied at least one minute of flow.
When the intervention of the anti-stagnation algorithm is over, if the device is configured as reserve, it is returned to minimum priority to
preserve it from wear.
11.1.11 Reserves and number of devices that participate in pumping
The multipump system reads how many elements are connected in communication and calls this number N.
Then depending on the parameters NA and NC it decides how many and which devices must work at a certain time.
NA represents the number of devices that participate in pumping.
NC represents the maximum number of devices that can work at the same time.
If there are NA active devices in a chain and NC simultaneous devices with NC smaller than NA, it means that at the most NC devices will start
at the same time and that these devices will exchange with NA elements. If a device is configured with reserve preference, it will be the last in
the starting order, so for example if I have 3 devices and one of these is configured as reserve, the reserve will be the third element to start,
whereas if I set NA=2 the reserve will not start unless one of the two active ones develops a fault.
See also the explanation of the parameter
8.6.8 - NA: Active devices;
8.6.9 NC: Simultaneous devices;
8.6.10 IC: Configuration of the reserve.
11.1.12 Wireless Control
As described in par. 9.4.3, the device can be connected to other devices by means of the proprietary wireless channel. There is therefore the
possibility of controlling particular operations of the system through signals received in remote mode: for example, depending on a tank level
supplied by a float it is possible to order it to be filled; with the signal arriving from a timer it is possible to vary the setpoint from SP to P1 to
supply irrigation.
These signals entering or leaving the system are managed by a control unit that can be bought separately from the DAB catalogue.
11.1.13 Modbus
Through the same communication control unit described in the previous paragraph it is possible
to control the pump via the Modbus communication protocol. Refer to the appropriate manual
for Modbus commands.
12. APP, DCONNECT CLOUD AND SOFTWARE UPDATE
The "Smart Solution" APP DConnect
is, together with the pump display, the interface for local control of the Esybox Max pump.
Via the DConnect APP you can update the product and configure the main parameters of the device with the convenience of an easy-to-use
and always handy APP.
The DConnect APP allows you to get the best out of the product: it is also possible to speed up the creation of your system through the DSync
solution (see dedicated section) and make the necessary updates (see dedicated section) directly from your smartphone without cumbersome
external objects.
Via the APP it is possible to interact locally with the product through the "Direct Connection" menu accessible directly
from the main page of the APP.
Menu - Direct connection
The DConnect CLOUD "Smart Solution" allows you to control your systems remotely both through the appropriate
internet portal:
dconnect.dabpumps.com
and through the DConnect APP itself via the appropriate menu "Your
installations", accessible directly from the APP main page.
Menu - Your Installations
NOTE 1: The DConnect Cloud remote control service requires registration with the portal and, after a trial period, it requires a subscription. All
information is available on the site:
www.internetofpumps.com
NOTE 2: This manual refers to DConnect APP menus, colours or descriptions may change.
To get the best out of the product and its interaction with the APP and the DConnect Cloud service, consult also the online documentation and
watch the demonstration videos. All the necessary information is available on the site:
www.internetofpumps.com
or
www.dabpumps.com
73

Publicité

loading

Ce manuel est également adapté pour:

Esybox max 60/120tEsybox max 85/120t