10. PROTECTION SYSTEMS
The device is equipped with protection systems to preserve the pump, the motor, the supply line and the inverter.
Depending on the type of error, the protection can stop the motor but when normal conditions are restored it can: cancel itself automatically
instantaneously or after a certain time following an automatic reset.
Some errors can be unlocked manually by pressing and releasing the ^ and ˅ buttons simultaneously.
Low pressure threshold on
suction [bar]
Blockage time for water lack [s]
Low pr. delay (KIWA) [s]
Delay in switching off [s]
Proportional gain coefficient
Integral gain coefficient
Maximum speed [rpm]
Active devices
Simultaneous devices
Configuration of the reserve
Max. exchange time [h]
Anti-blocking function
Antifreeze
Function I1
Function I2
Function I3
Function I4
Function output 1
Function output 2
Change password
Anticycling Function AY
Display indication
PD
FA
Display indication
PH
Cutout due to pump overheating
BL
Blockage due to water lack
BP1
Blockage due to reading error on the delivery pressure sensor
BP2
Blockage due to reading error on the suction pressure sensor
PB
Blockage due to supply voltage outside specifications
OT
Blockage due to overheating of the power stages
OC
Blockage due to motor overload
SC
Blockage due to short circuit between the motor phases
ESC
Blockage due to short circuit to earth
HL
Hot liquid
NC
Blockage due to motor disconnected
Ei
Blockage due to i-th internal error
VI
Blockage due to i-th internal voltage out of tolerance
EY
Block for cyclicality abnormal detected on the system
Table 20 Indications of blockages
ENGLISH
1,0
15
2
10
0,5
1,2
5500
N
NA
1 (Auto)
2
1(Enabled)
1(Enabled)
0 (disabled)
0 (disabled)
0 (disabled)
0 (disabled)
2
2
0
0 (Disabled)
Table 18
Alarm in the fault log
Description
Irregular switching off
Problems in the cooling system
Table 19 Alarms
Blockage conditions
Description
68

Publicité

loading