Fill the pump (par 5.1)
•
Open a utility on delivery
•
Provide electric power supply
•
Connect to the pump via App to carry out assisted configuration
The system starts and checks the presence of water in delivery. If a regular flow of water is detected, the pump is primed and starts its pressure
boosting work.
Operation
Once the electropump is primed, the system starts regular operation according to the configured parameters: it starts automatically when the tap
is turned on, supplies water at the set pressure (SP), keeps the pressure constant even when other taps are turned on, stops automatically after
time T2 once the switching off conditions are reached (T2 can be set by the user, factory value 10 sec).
7. THE KEYPAD AND THE DISPLAY
The user interface is composed of a keypad with 2.8'' display and with POWER,
COMM, ALARM warning leds as can be seen in Figure 13.
The display shows the values and the statuses of the device, with indications on the
functionality of the various parameters.
The functions of the keys are summed up in Table 4.
The MODE key allows you to move on to the next items in the same menu. Holding it down for at least 1 sec allows
you to skip to previous menu item.
WHITE LED
On with a fixed light: the machine is powered
POWER
Flashing: the machine is disabled
RED LED
ALLARM
On with a fixed light: active wireless communication
BLUE LED
Slow flashing: wireless communication not available due to problems
COMMUNICATION
Fast flashing: association with other wireless devices in progress
Holding down the "^" key or the "˅" key allows the automatic increase/decrease of the parameter selected. After the "^" key or the "˅" key has
been held down for 3 seconds, the automatic increase/decrease speed increases.
When the ^ key or the ˅ key is pressed the selected value is modified and saved immediately in the permanent memory
(EEprom). If the machine is switched off, even accidentally, in this phase it does not cause the loss of the parameter that has just
been set.
The SET key is only for leaving the current menu and is not necessary for saving the changes made. Only in particular cases
The SET key allows you to leave the current menu.
Decreases the current parameter (if it is an editable parameter).
Increases the current parameter (if it is an editable parameter).
On with a fixed light: the machine is blocked by an error
ENGLISH
Figure 13
Table 4
51