Relays; Energy-Manager(In Relay Menu Item) - Fronius Primo 3.0-1 Instructions De Service

Masquer les pouces Voir aussi pour Primo 3.0-1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Relays

Activate relay, relay settings, relay test
Setting range
* these are only shown if the 'E-Manager' function has been activated under 'Relay mode'.
Relay mode
for selecting the different functions of the floating switch contact in the data communica-
tion area:
-
-
-
Setting range
Factory setting
Relay test
Function test to determine whether the floating switch contact switches
Switch-on point (only if 'Energy Manager' function is activated)
for setting the effective power limit beyond which the floating switch contact is switched on
Factory setting
Setting range
Switch-off point (only if 'Energy Manager' function is activated)
for setting the effective power limit beyond which the floating switch contact is switched off
Factory setting
Setting range
Energy-Manager
The 'Energy-Manager' function can be used to activate the floating switch contact in such
(in Relay menu
a way that it functions as an actuator.
item)
Thus a consumer that is connected to the floating switch contact can be controlled by spec-
ifying a switch-on or switch-off point that depends on the feed-in power.
The floating switch contact is automatically switched off,
-
-
-
-
Relay mode / Relay test / Switch-on point* / Switch-off point*
Alarm function
Active output
Energy Manager
ALL / Permanent / OFF / ON / E-Manager
ALL
Alarm function:
Permanent /
Switch the floating switch contact for permanent and temporary ser-
ALL:
vice codes (e.g. brief interruption to energy being fed into the grid, a
service code occurs a certain number of times a day - can be adjusted
in the 'BASIC' menu)
Active output:
ON:
The floating NO contact is on all the time the inverter is in operation
(as long as the display is not dark or is displaying something).
OFF:
The floating NO contact is off.
Energy Manager:
E-Manager:
Further details on the 'Energy Manager' function may be found in the
"Energy Manager" section.
1000 W
Switch-off point - max. nominal output of inverter / W / kW
500
0 - Switch-on point / W / kW
if the inverter is not feeding any power into the grid,
if the inverter is manually switched into standby mode,
if the effective power is < 10% of nominal output,
in the event of insufficient insolation.
31