6.3 Air fil ter
Risk of fire and ex plo sion caused by in flam ma ble
sub stances.
For clean ing the fil ter el e ment, do not use any
flam ma ble or ag gres sive ma te ri als.
In the work area, do not smoke, and pre vent
open flames or sparks.
Re place the fil ter el e ment:
when the fil ter el e ment is dam aged
if there is wet or oily con tam i na tion
if en gine per for mance suf fers
at least once a year
Do not al low dirt into the air chan nel and car bu ret tor.
Never run the en gine with out an air fil ter.
When clea ning the ma chi ne with a pres su re was her,
do not hold it di rect ly over the air fil ter or pre-se pa ra tor.
6. Main ten an ce en gi ne
Clean the in takes (1).
Loosen the wing nuts (2).
Re move and clean the fil ter cover (3) with the wing nut.
Care fully pull the fil ter car tridge (4) out of the fil ter hous ing (5).