Converting CS 1028
To convert the burner
,
Conversion to a different type of
gas should only be performed by an
authorized gas technician.
Turn off the main gas supply (if the
appliance has been installed) and
disconnect the appliance from the
main electrical power supply before
proceeding.
When converting to a different type of
gas, the jets and needle valves have to
be changed.
Maximum output
Gas type
Natural Gas
LP Gas (Propane)
Minimum output
Gas type
Natural Gas
LP Gas (Propane)
14
All manuals and user guides at all-guides.com
BTU/hr
kW
27,600
8.1
22,200
6.5
BTU/hr
kW
5,700
1.67
5,700
1.67
The following jets and needle valves
should be installed into their respective
burners. Follow codes accordingly.
Code Jet size
Natural
230
gas
LP Gas
135
(Propane)
Code
Needle
(Ø mm)
valve size
(Ø mm)
2.30
110
1.10
1.35
70
0.70