Commissioning
6.1
Sensing range setting
8021879.1CXK /2022-08-16 | SICK
Subject to change without notice
Table 1: Overview of pin assignment
-2X329x
1
+(L+)
2
Q
3
-(M)
4
Q
4
3
1
2
Q1
Figure 6: Sensing range setting
1
Position the object at the required distance and move it into the beam path of the
device (note the min. and max. ranges,
2
The sensing range is adjusted by pressing the single teach-in button (yellow LED
lights up).
NOTE
Note: The sensor automatically places the switching point in the object (teach-in offset
15 mm). Exception: When manually adjusting a mm value using an IO-Link, we recom‐
mend placing the switching point in the object.
NOTE
We recommend making the adjustments using an object with a low remission.
NOTICE
Do not operate the teach-in button using sharp objects.
OPERATING INSTRUCTIONS
-2X119x
+(L+)
Q
-(M)
Q
1 = BN
4
2 = WH
3 = BU
4 = BK
1
0.09 mm
2
AWG 28
see figure 6, page
O P E R A T I N G I N S T R U C T I O N S | PowerProx Micro - WTT2SL(C)
C-2Xxx9xAxx
+(L+)
MF
-(M)
Q
/C
1
1 = BN
3
2 = WH
3 = BU
4 = BK
2
0.09 mm
2
AWG 28