show platform software ilpower details
show controllers ethernet-controller phy detail
show power inline upoe-plus (applicable to modules supporting UPoE+ like C9400-LC-48H)
**snip**
3. Collecter des informations spécifiques à la plate-forme
show platform software iomd redundancy
show platform
show tech-support platform | redirect bootflash:showtechplatform9400.txt
4. Collecter les vidages du registre de ports
test platform hard poe get <line card slot #> global
test platform hard poe get <line card#> port <port# in question for PoE>
test platform hard poe get 3 global <++ line card slot number 3, use respective line card number
test platform hard poe get 3 port 1 <++ line card slot number 3, port 1, use respective line
card/port number
C9400#test platform hard poe get 2 global
Global Register for slot 2 0x00FFFFFF 0x00FFFFFF 0x80001304 0x000000C1 0x00000000 0x00000700
0x0FFD0FFD 0x00000015 0x0000000E 0x00000000 0x005AD258 0x00003A0A 0x00000700 0x00000000
0x00000000 0x00000000 0x00000000 0x00000000 0x00000000 0x00000000 POE FW loaded successfully <--
success POE health status : GOOD <-- success POE PSE FW ver :19 POE Abstraction layer FW ver =
14
5. Récupérez le mappage IFM pour les ports. Ceci est utile pour que le TAC puisse interpréter
d'autres sorties recueillies.
show platform software fed active ifm mappings
C9400#show platform software fed active ifm mappings
Interface
GigabitEthernet1/0/1
GigabitEthernet1/0/2
GigabitEthernet1/0/3
**snip**
6. Collecter les traces IOMD
6.1 Réglez le niveau de trace de l'IOMD sur « verbose ». Utilisez le numéro de module en
question
set platform software trace iomd <module_number>/0 poe verbose
set platform software trace iomd 3/0 poe verbose <++ Here 3 is line card slot#, use respective
slot number as applicable
6.2 Shut/no shut le port en question.
IF_ID Inst Asic Core Port SubPort Mac Cntx LPN GPN Type Active
0x8
0
0
0
0x9
0
0
0
0xa
0
0
0
0
0
4
4
1
1
4
4
2
2
4
4
1
101 NIF
Y
2
102 NIF
Y
3
103 NIF
Y