show power inline
show power inline police
show interface status
show platform software ilpower details
show stack-power budgeting
show stack-power detail
show controllers ethernet-controller phy detail
show controllers power inline module 1
show platform frontend-controller version 0 1
show platform frontend-controller manager 0 1
show platform frontend-controller subordinate 0 1
show platform software ilpower system 1
show power inline Gi<> detail
3. Collecter la version "frontend-controller" et le vidage du contrôleur
3.1 show platform frontend-controller version 0 <switch number>
C9348U#show platform frontend-controller version 0 1
respective switch number in question
Switch 1 MCU:
Software Version
129
System Type
Device Id
Device Revision
Hardware Version
Bootloader Version 17
3.2 show Controllers Power inline module <switch number>
show controllers power inline module 1 <++ 1 is switch number, use respective switch no. in
question
3.3 Lisez les registres du contrôleur.
test frontend-controller read-poe <MCU no> module <switch member#>
Vous devez utiliser l'accès console pour imprimer ce résultat. Recueillez cette sortie pour tous
les MCU sur le commutateur en question.
Note: Pour un module UPoE, le numéro MCU est compris entre 1 et 24 et pour un module POE+,
entre 1 et 12.
test frontend-controller read-poe 1 module 1 <++ MCU #1 of switch 1,use respective switch number
as applicable
test frontend-controller read-poe 2 module 1 <++ MCU #2 of switch 1,use respective switch number
as applicable
test frontend-controller read-poe 3 module 1 <++ MCU #3 of switch 1,use respective switch number
as applicable
...
...
test frontend-controller read-poe 12 module 1 <++ MCU #12 of switch 1,use respective switch
number as applicable
...
...
<++ Output for MCU 13-24 is applicable only to UPoE devices
...
6
2
0
41
<++ 1 is switch number here, use your