14. Troubleshooting
Fault
Engine does not start
Generator has too little or no
voltage
15. Maintenance schedule
Please adhere to the following maintenance periods in order to ensure a failure-free operation.
IMPORTANT! The equipment must be filled with engine oil and fuel before it is started.
Before each use
Checking the engine oil
Changing the engine oil
Checking the air filter
Cleaning the air filter
Cleaning the petrol filter
Visual inspection of the
equipment
Cleaning the spark plug
Checking andreadjust-
ing the throttle vale on
the carburetor
Cleaning the cylinder
head
Set the valve play
Important: The positions marked with "x*" should only be carried out by an authorized dealer.
Possible cause
Automatic oil cut-out has not responded
Spark plug fouled
No fuel
Electronic defective
Over-current circuit-breaker has trig-
gered
Air filter dirty
After an operating
period of 20 hours
X
For the first time,
then every 50
hours
X
X
www.scheppach.com
Remedy
Check oil level, top up engine oil
Clean or replace spark plug
Refuel / have the petrol cock checked
Contact your dealer
Actuate the circuit-breaker and reduce
the consumers
Clean or replace the filter
After an oper-
After an operat-
ating period of
ing period of 100
50 hours
hours
X
X
X
Distance: 0.6
mm, replace if
necessary
After an
operating
period of
300 hours
Change the
filter insert if
necessary
X*
X*
X*
GB | 25