Our warranty will be voided if the equipment is used
in commercial, trade or industrial businesses or for
equivalent purposes.
5. Technical data
Generator
Protection type
Continuous Power P
(S1)
nenn
Power P
(S2/5min)
max
Nominal voltage U
nenn
Rated current I
nenn
Frequency F
nenn
Type drive motor
Engine displacement
Max. power (motor)
Fuel
Tank capacity
Engine oil
Use at ⅔ engine load
Weight
Sound pressure level L
pA
Sound power level L
WA
Uncertainty K
Power factor cos ϕ
Performance class
Quality class
Spark plug
Operating mode S1 (long use)
The machine can be used continuously with the indi-
cated power.
Inverter
IP23M
700 W
800 W
230 V~
3 A
50 Hz
4 stroke air-cooled
56 cm³
1,3 kW/1,76 PS
Unleaded fuell
3 l
0,28 l
(15W-40)
ca.0,88 l/h
12 kg
79,4 dB(A)
95 dB(A)
1,97 dB (A)
1
G2
B
A5RTC
www.scheppach.com
Operating mode S2 (Short term use)
The machine can be used in the short term with the
indicated power.
Acceptable ambient temperature:
-5 to +40 °C
Height: 1000 m above NN
rel. air humidity: 90 % (not condensed)
6. Safety information
These operating instructions provide places concern-
ing your safety which are marked with this indication:
m
Furthermore this manual contains other important
sections which are marked with the word "ATTEN-
TION!".
m Attention!
While using the machine some safety precautions
must be observed to prevent injuries and damage.
Read the directions with due care. If you give the
equipment to any other person, give them these op-
erating instructions as well. We assume no liability
for injuries or damages which are a results of non-
compliance of this manual and its safety notes.
m DANGER
Failure to follow these instructions may cause serious
danger to life of danger or fatal injuries.
m WARNING
Failure to follow these instructions may cause danger
to life or danger of serious injuries.
m CAUTION
Failure to follow these instructions may cause light to
medium risk of injury.
m NOTE
Failure to follow these instructions may cause danger
of damage of the engine or other property values.
1.
No modifications are allowed to be made to the
generator
2.
The speed preset by the manufacturer may not
be changed. The generator or connected devices
could be damaged.
Risk of poisoning! Fumes, fuels and lubricants
3.
are toxic. Do not breath in the fumes.
Fire risk! Petrol and petrol fumes are highly flam-
4.
mable and explosive.
GB | 19