NOTIFICATION LIST
WPM (CN) 234727, 239693
Message code Notifica-
tion from
20040
Heat pump
20041
Heat pump
20045
Heat pump
20046
Heat pump
20050
Heat pump
20051
Heat pump
20057
Heat pump
20058
Heat pump
20059
Heat pump
20060
Heat pump
20061
Heat pump
20062
Heat pump
20063
Heat pump
20064
Heat pump
20065
Heat pump
20066
Heat pump
20067
Heat pump
20068
Heat pump
20069
Heat pump
20070
Heat pump
20071
Heat pump
20072
Heat pump
20073
Heat pump
20074
Heat pump
20075
Heat pump
20076
Heat pump
20077
Heat pump
20078
Heat pump
20079
Heat pump
20080
Heat pump
20081
Heat pump
20084
Heat pump
20085
Heat pump
20091
Heat pump
20093
Heat pump
20095
Heat pump
WPMsystem
Reason for fault code being triggered
Temperature limiter for inverter of high pressure
compressor has been triggered.
Rotor stalled limiter for high pressure compressor
has been triggered.
Speed deviation between set and actual compres-
sor values for a defined time (low pressure compres-
sor in the case of two compressors)
Speed deviation between set and actual compres-
sor values for a defined time (high pressure com-
pressor in the case of two compressors)
Temperature limiter for minimum heat source flow
temperature has responded
Temperature limiter for minimum heat source re-
turn temperature has responded
Major inverter fault: Inverter IGBT excess current
Major inverter fault: PFC IGBT excess current
Major inverter fault: DC intermediate circuit excess
voltage
Major inverter fault: DC intermediate circuit under-
voltage
Major inverter fault: AC input excess voltage
Major inverter fault: AC input undervoltage
Major inverter fault: Voltage differences between
the three input phases
Major inverter fault: Desaturation
Major inverter fault: Inverter IGBTs excess tempera-
ture
Major inverter fault: PFC IGBTs excess temperature. Inverter fault
Major inverter fault: Rotor does not turn as expect-
ed.
Major inverter fault: Arithmetic fault in the measur-
ing and analysis process
Major inverter fault: Input relay open
Major inverter fault: Current differences between
the three inverter IGBTs
Major inverter fault: Current differences between
the three PFC IGBTs
Major inverter fault: LV range exceeded
Major inverter fault: Motor excess speed
Minor inverter fault: DC intermediate circuit under-
voltage
Minor inverter fault: Torque limit reached
Minor inverter fault: Modbus communication is
faulty
Minor inverter fault: Compressor scroll excess tem-
perature
Minor inverter fault: Compressor motor excess tem-
perature
Minor inverter fault: Switching circuit excess tem-
perature
Minor inverter fault: Inverter IGBTs excess temper-
ature
Minor inverter fault: PFC IGBTs excess temperature
Minor inverter fault: Temperature differences be-
tween the three inverter IGBTs
Minor inverter fault: Temperature differences be-
tween the three PFC IGBTs
Minor inverter fault: Communication between an-
alogue/digital converter and auxiliary processor is
faulty
Low relevance communication objects have been
incorrectly transferred repeatedly between the IWS
and inverter.
INV major fault central fault 1
Possible cause of fault / remedy
Value is reset automatically. If necessary, clean the
inverter heat sink.
Value is reset automatically.
Inverter or compressor not working correctly. Check
inverter BUS connection.
Inverter or compressor not working correctly. Check
inverter BUS connection.
Check brine circuit
Check brine circuit
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault
Inverter fault. Check leads and the relevant plug-in
connectors, and replace if faulty. Check the power
supply to the inverter.
Inverter fault