Retarder Prover 60x80
To carry out connection, connect the mains pipe
to the appliance connection pipe (ø ¾") (1),
interposing a shut-off cock (A)
water supply when necessary. Downstream from
this, install some easily reachable filters.
The water temperature must be between 5°C and
50°C.
The water pressure must be enough to guarantee
a correct functioning (see the following table).
Connect the safety discharge (2) present at the
top of the appliance, directly to the water supply.
8.5.
Inspection
The appliance is delivered in conditions that it can
be started-up by the user.
This functionality is guaranteed by passing the
tests (electric inspection - functional inspection,
9.
TECHNICAL NOTES
9.1. Accessory wheels assembly kit
Unscrew the feet (1) until they are
removed completely
Fix the wheel (2) and base (3) board to
the bottom of the cabinet using the
screws supplied.
1
to interrupt the
appearance inspection) and relative certification
through the specific attachments.
25
ENGLISH
1
The screws of each wheel can be inserted
in the envisioned 4 Ø 6mm holes.
GB
2
3
2