5. CHANGING NOSE ASSEMBLIES
Spare parts number circled with"
nut changed.
Please take the process as follows:
Disconnect the tool from the compressed air supply.
1)
Set the spanner onto lock nut (Item 2), unscrew the nose piece (Item 1)counter
2)
clockwise.
Unscrew the nose casing off with the spanner.
3)
Set the spindle (Item 9) with the spanner, unscrew and remove the adaptor nut
4)
(Item 4)
Change the drive shaft (Item 7), mandrel (Item 6), reducing sleeve (Item 5)
5)
accordingly.
Tighten the spindle (Item 9) and the adaptor nut (Item 4) clockwise with a spanner.
6)
Screw on the nose casing (Item 3), change and set the nose piece (Item 1) in
7)
exact pistion according to the right mandrel protrusion, then lock nose piece lock
nut with spanner.
Warning: The air supply must be disconnected when changing nose
assemblies.
○
" shall be changed completely, if the size of insert
www.degometal.com
19