OPERATING PROCEDURE
•
Ensure that either a nose assembly or
swivel head suitable for the fastener is fitted.
•
Connect the tool to the air supply.
•
Insert the fastener stem into the
nose of the tool. If using a nose Assemb
ly,the fastener should remain held in by the
vacuum system. If not, adjust the vacuum
extraction rotary valve 60.
•
If using a swivel head, the vacuum
extraction
is
disabled
themselves will grip the fastener.
•
Bring the tool with the fastener to
the application so that the protruding
fastener enters squarely the hole of the
application.
•
Fully actuate the trigger. The tool
cycle will broach the fastener and with
The air supply must be disconnected when fitting or removing nose assemblies
4. CHANGING NOSE ASSEMBLIES
Nose assemblies do NOT include nose tips. Nose tips must be ordered separately.
Item numbers in bold refer to nose assembly components in all nose tip tables.
• Lightly coat iaws 4 with Moly Lithium grease*.
• Drop jaw 4 into iaw Housing 3 or chuck collet 9 depending on which nose assembly you
are using.
• Insert jaw spreader 5 into jaw housing 3 or insert front spring guide 10 into chuck collet 9.
• Locate buffer 6 on jaw spreader 5.
• Locate spring 7 onto jaw spreader 5 or onto front spring guide 10 .
• Screw rear spring guide 11 into chuck collet 9 .
• Fit I ocking ring 8 onto the jaw spreader housing of the tool.
• Holding tool pointing down, screw the assembled jaw housing 3 or chuck collet 9 onto the
jaw spreader housing and tighten with spanner*.
• Screw the nose tip into nose casing 1 and tighten with spanner*.
• Place Nose casing 1 over jaw housing 3 or chuck collet 9 and screw onto the tool,
tightening with spanner*.
but
the
jaws
IMPORTANT
IMPORTANT
www.degometal.com
standard nose assemblies the broken stem
will be projected to the rear of the tool .
ADJUSTING THE VACUUM EXTRACTION
•
Using a screwdriver, turn rotary
valve 60 until the air flow at the rear of the
tool ceases.
•
With the nose of the tool pointing
downwards, insert a fastener into the nose
and hold it into position.
•
Turn the rotary valve either way until
there is sufficient suction to retain the
fastener
.
20