Télécharger Imprimer la page

Tennant T3 Opérateur Manuel page 32

Publicité

Les langues disponibles

Les langues disponibles

OPERATION
TROUBLESHOOTING - - continued
PROBLEM
ec
- H2O Model:
ec- -H2O system indicator light
blinks red and alarm sounds
ec- H2O Model:
ec- -H2O system indicator light
solid red
ec- H2O Model:
ec- -H2O system indicator light
does not turn on
ec- H2O Model:
No water flow
BATTERY METER LED FAULT CODES
CODE
FAULT
(Flashing LED Bars)
One
Low voltage shut--off.
Scrubbing function stops.
Two
Battery charge level getting low.
Three
Drive motor tripped.
Short circuit to drive motor.
Four
Battery lockout.
Eight
Controller tripped.
Ten
High battery voltage reading
No Bars
Sleep mode
Bars Rippling
Throttle engaged.
32
CAUSE
Mineral deposit build--up in module
Low water conductivity
Defective module
Defective light or module
Clogged module
Defective solution pump
(Drive Model)
Home
Find... Go To..
SOLUTION
Flush module (See ec- -H2O MODULE
FLUSH PROCEDURE). If indicator
light starts flashing within 1--10
seconds, repeat flush procedure. If in-
dicator light starts flashing after a
minute of scrubbing, the water may
have low conductivity.
Add 8 ml of salt to every 40 L of water.
Contact Service Center
Contact Service Center
Contact Service Center
Replace solution pump
SOLUTION
Recharge batteries.
Check battery connection.
Recharge batteries.
Remove overload condition and reset key.
Contact Service Center.
Recharge batteries immediately.
Contact Service Center.
Check battery connections.
Turn key to restore.
Release activation bail.