ON- -BOARD BATTERY CHARGER FAULT CODES
LED FAULT CODE
FAULT
3 LED's flash once
Loose charger cable connection.
repeatedly
Loose or damaged battery cable.
Defective Battery.
3 LED's flash twice
Input voltage is out of range.
repeatedly
3 LED's flash three
Safety thermostat exceeded maximum internal
times repeatedly
temperature.
3 LED's flash four
Output current exceeds a limit.
times repeatedly
100% LED flashes
Abnormal cycle. Safety timer exceeded the 18
while the 50% and
hour charging time.
75% LED's are off.
Tennant T3/T3+ (01- -08)
Home
Find... Go To..
OPERATION
SOLUTION
Check charger cable connection.
Check battery cable connections.
Replace battery.
Try using a different wall outlet.
Open battery compartment to promote air
circulation or move machine to a cooler
climate.
Disconnect charger cord, wait 30 seconds,
then plug back in. If fault continues replace
charger or Contact Service Center.
Battery maintenance required or replace
battery.