IMPORTANT NOTICE
•
Do not carry out maintenance or inspection work yourself. This work
must be carried out by qualified service personnel with suitable tools
and resources for the work.
•
Do not place any foreign material (branches, sticks, etc.) in the air
inlet or outlet of the unit. These units are fitted with high speed fans
and contact with any object is dangerous.
•
This appliance must be used only by adult and capable people,
having received the technical information or instructions to handle this
appliance properly and safely.
•
Children should be supervised to ensure that they do not play with
the appliance.
•
Install the unit in a place not accessible by the general public.
3 IMPORTANT NOTICE
This air conditioner has been designed for standard air
conditioning for human beings. For use in other applications,
please contact your Hitachi dealer or service contractor.
The air conditioning system should only be installed by qualified
personnel, with the necessary resources, tools and equipment,
who are familiar with the safety procedures required to
successfully carry out the installation.
The supplementary information about the purchased products
is supplied in a CD-ROM, which can be found bundled with the
outdoor unit. In case that the CD-ROM is missing or it is not
readable, please contact your Hitachi dealer or distributor.
PLEASE READ THE MANUAL AND THE FILES ON THE
CD-ROM CAREFULLY BEFORE STARTING WORK ON THE
INSTALLATION OF THE AIR CONDITIONING SYSTEM.
Failure to observe the instructions for installation, use and
operation described in this Manual may result in operating failure
including potentially serious faults, or even the destruction of the
air conditioning system.
It is assumed that the air conditioning system will be installed
and maintained by responsible personnel trained for the
purpose. If this is not the case, the customer should include all
the safety, caution and operating signs in the native language of
the personnel responsible.
4 APPLICABLE MODEL
This air panel is applicable to the following indoor unit model:
2
PMML0570 rev.0 - 01/2021
?
•
•
•
•
Do not install the unit in the following places, as this may lead to
a fire, deformities, rusting or faults:
•
•
•
•
Do not install the unit in places where silicon gas is present. Any
silicon gas deposited on the surface of the heat exchanger will
repel water. As a result, the condensate water will splash out
of the collection tray and into the electrical box. Water leaks or
electrical faults may eventually be caused.
Do not install the unit in a place where the current of expelled
air directly affects animals or plants as they could be adversely
affected.
There are detailed information about unit installation, service
space, wiring diagrams, electrical connection, refrigerant charge,
in the corresponding chapter, please read the corresponding
chapter carefully before starting work on the installation.
Air panel
P-AP56NAM
P-AP56NAMS
P-AP56NAMR
N O T E
The air in the room should be renewed and the room ventilated every
3 or 4 hours.
The system fitter and specialist shall provide anti-leak safety in
accordance with local regulations.
The installer and system specialist shall secure safety against the
refrigerant leakage according to local regulations or standards. The
following standards may be applicable, if local regulations are not
available. International Organization for Standardization, ISO5149 or
European Standard, EN378 or Japan Standard, KHKS0010.
Electrical wiring must comply with national and local regulations.
Contact your local authority in regards to standards, rules, regulations,
etc..
Places where oil is present (including oil for machinery).
Places with a high concentration of sulphurous gas, such as
spas.
Places where flammable gases may be generated or circulate.
Places with a saline, acidic or alkaline atmosphere.
Indoor unit model
RCIM-(0.4- 2.5)FSRE