9
Cleaning
26
27
-
Figures
ATTENTION
Improper use of the device poses a risk
of damage to property! You should
therefore observe the following safety
instruction:
26
27
Clean the inlet filter (G) and the
-
filter (R) behind the coupling of
the water connection if it is dirty.
10
Problems with the device
10.1 Troubleshooting the
Faults usually occur if the device has not been handled, cared for or maintained properly. The
following table contains the most common faults and remedies to eliminate these faults. If
you have any other problems, please contact your nearest service centre authorised by the
manufacturer, or your nearest authorised specialist dealer.
Fault
Cause
Battery capacity to low. Battery
charge indicator (B) flashes green
Device does not
start
Device overheating, battery status
indicator (B) flashes green
Water supply interrupted or filter
blocked
Nozzle or extension blocked
No pressure is
built up, or the
Inlet hose is leaking at the con-
pressure varies
nection, air is being drawn in
Filter on suction hose not comple-
tely under the water surface
On initial start-up or
Completely dry the pump in the
after recommissio-
device
ning after a longer
downtime, the
device does not
pump from open
containers.
Status display batt.;
1 display flash, then
Low voltage cutoff
all 4 displays flash
Do not immerse the device in water
or spray or clean it with water. The
device must be protected against
moisture.
Clean the outside of the device with a
damp cloth or soft brush. Do not use
abrasives or harsh cleaning agents.
Ensure that the ventilation slots are free
of dirt.
Only use original GLORIA spare parts
(https://shop.gloriagarten.de).
Repairs must be carried out by a
GLORIA service point.
and the battery charger
Remedy
Charge the battery
Allow the battery to cool down
Ensure a correct water supply
Clean the filter and the nozzle. Remove
any dirt in the extension.
Replace the connector if necessary
Completely immerse the hose end
with filter into water
First connect device to the water
supply (see section 7.2) and leave
running for approx. one minute
You can then proceed working with
the water supply from open contai-
ners (see section 7.3)
Charge the battery
34